Hepworth Heating Ltd.,
Nottingham Road, Belper, Derbyshire. DE56 1JT
General/Sales enquiries:
Tel: (01773) 824141 Fax: (01773) 820569
One Contact Local Service
Customer Services:
Tel: (01773) 828100
Fax: (01773) 828070
221785B.11.00
All replacement parts
All labour charges
All call-out charges
Thank you for installing a new Glow-worm appliance in your home.
Glow-worm appliances' are manufactured to the very highest standard so we are pleased to offer our customers' a
Comprehensive First Year Guarantee.
Attached to the center of these instructions is your Guarantee Registration Card,
which we recommend you complete and return as soon as possible.
If this card is missing you can obtain a copy or record your registration by telephoning the
Heatcall Customer Service number 01773 828100.
Our Guarantee gives you peace of mind plus valuable protection against breakdown by covering the cost of:
Guarantee Registration
Open Flue Boiler
This is a Cat I
2H
Appliance
BS 6332
BS 5258
Reference in these instructions to British Standards and Statutory
Regulations/Requirements apply only to the United Kingdom.
The instructions consist of three parts, User, Installation and Servicing Instructions, which includes the Guarantee Registration Card.
The instructions are an integral part of the appliance and must, to comply with the current issue of the Gas Safety (Installation and Use)
Regulations, be handed to the user on completion of the installation.
To be left with the user
Instructions for Use
Installation and Servicing
G.C. No. 41 319 48
REGISTER YOUR GLOW-WORM APPLIANCE
FOR 1ST YEAR GUARANTEE PROTECTION
CALL 0208 247 9857
40CF
2143
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - Installation and Servicing

Hepworth Heating Ltd.,Nottingham Road, Belper, Derbyshire. DE56 1JTGeneral/Sales enquiries:Tel: (01773) 824141 Fax: (01773) 820569One Contact Local S

Strona 2 - Important Information

10221785B5.1 Control Box RemovalRemove the electrical control box securing screw, see diagram5.1. Pull the control box down at the front and pull for

Strona 3

11221785B5 Electrical Connection8049BROWNBLUEGRN/YELBLUEBROWNNEEARTH230V~50Hz PERMANENT MAINSSUPPLY FUSED AT 3 AMPBLKTHERMOSTAT NC CGRN/YELBROWNELECTR

Strona 4

12221785BDiagram 6.3SPARK GAPAND FLAME DIMENSION2145HEXPILOT BURNERSECURINGNUT2.5 TO 5.0mm(1/8 in) (3/16 in)10 to 14mmSPARKELECTRODE6 CommissioningT

Strona 5 - Diagram 1.1

13221785BDiagram 6.5SECURING SIDE PANELS2158SIDEPANELSECURINGSCREW (6)6 CommissioningDiagram 6.4BURNERSUPPLYTUBEPILOT SUPPLY TUBEBLUEGREEN/YELLOWBROWN

Strona 6 - 2 Flue and Ventilation

14221785BDiagram 8.2MULTI-FUNCTIONALCONTROL FILTERS2142FINE INLETSCREENPILOTFILTERDiagram 8.1MULTI-FUNCTIONALCONTROL CONNECTIONS5313HEX SCREW (4)&apos

Strona 7 - 3 Water Systems

15221785B8 Servicing and Replacement of Parts8.6 Main InjectorGain access as Section 8.1.Remove main burner as Section 8.2.Remove the main burner inje

Strona 8

16221785BDiagram 8.8FLUE BLOCKAGESAFETY DEVICEELECTRICALCONNECTIONS5315SECURINGSCREW (2)PHIALSAFETYDEVICELOCKNUTDisconnect the pilot supply tube by un

Strona 9

17221785BPILOT WILL NOT LIGHTSTART HERECheck flue blockage safety device has not operated, check gas line-open all cocks, rectify any blockages, purge

Strona 10 - 5 Electrical Connection

18221785B9 Fault FindingRe-connect boiler flue blockage safety device to points A and B. Disconnect thermocouple at connection point D of the gas val

Strona 11 - 6 Commissioning

19221785B9 Fault FindingDiagram 9.4FAULT FINDING0899/AFaulty gas valve.Replace.Turn boiler thermostat to "O'.Does main burner extinguish.Boi

Strona 12

2221785BImportant InformationIntroduction 3Lighting the Boiler 4General Data 1 5Flue & Ventilation 2 6Water Systems 3 7Installation 4 8Electrical

Strona 13 - 7 User Information

20221785B10 Replacement PartsKey No Part No Description G.C. Part No.8053Diagram 10.11391075126243181114If replacement parts are required, apply to yo

Strona 14

3221785BInstructions for UseIntroductionPlease read these instructions and follow them carefully for thesafe and economical use of your boiler.The Ult

Strona 15 - 8.8 Pilot Burner Injector

4221785BInstructions for UseConnecting an Electrical PlugThe colours of three core flexible cable are, Brown - live, Blue- neutral, Green and Yellow -

Strona 16 - 8.13 Ignition Lead

5221785B1 General Notes and InformationThis boiler is for use on natural gas G20.Wherever possible, all materials, appliances and componentsto be used

Strona 17 - 9 Fault Finding

6221785BOn completion test the gas installation for soundness using thepressure drop method and suitable leak detection fluid, purgein accordance with

Strona 18

7221785BThe flue must be installed in accordance with therecommendations in the current issue of BS5440 Part 1.The flue should be kept as short as pos

Strona 19

8221785B1metre Min.27 metresMax.22mm VENT &15mm COLD FEEDTO BE FITTED INACCORDANCEWITH BS 6798INDIRECTCYLINDERALTERNATIVESYSTEMCONTROLVALVESHEATIN

Strona 20 - 10 Replacement Parts

9221785BNote: It is NOT recommended that the boiler be placed in anupright position. If it is unavoidable great care must be taken notto damage the g

Komentarze do niniejszej Instrukcji